TIVM1L光隔離探頭The Tektronix TIVM and TIVH Series IsoVu™ Measurement Systems offer galvanically isolated measurement solutions for accurately resolving high bandwidth, differential signals up to ±2500 V in the presence of large common mode voltages with the best in class common mode rejection performance across its bandwidth.
Product Description
The TIVM and TIVH Series (IsoVu) products can be used on most Tektronix oscilloscopes with the TekVPI interface and on MSO/DPO70K series oscilloscopes with the TCA-VPI50 adapter. IsoVu utilizes an electro-optic sensor that converts the electrical signal from the sensor tip cables to an optical signal, which electrically isolates the device-under-test from the oscilloscope. IsoVu incorporates four separate lasers, an optical sensor, five optical fibers, and sophisticated feedback and control techniques. The sensor head, which connects to the test point, has complete electrical isolation and is powered over one of the optical fibers (No batteries required). IsoVu is an ideal solution for users making the following measurements:
TIVM1L光隔離探頭
TIVM Series Common mode rejection ratio, sensor tip cables, and adapters (Typical)
Sensor tip cable/adapter | DC | 1 MHz | 100 MHz | 200 MHz | 500 MHz | 1 GHz |
---|
MMCX Sensor tip cables |
IVTIP1X | 160 dB | 124 dB | 120 dB | 110 dB | 100 dB | 90 dB |
IVTIP5X | 160 dB | 124 dB | 120 dB | 110 dB | 100 dB | 90 dB |
IVTIP10X | 160 dB | 124 dB | 120 dB | 110 dB | 100 dB | 90 dB |
IVTIP25X | 160 dB | 120 dB | 110 dB | 100 dB | 100 dB | 90 dB |
IVTIP50X | 160 dB | 116 dB | 100 dB | 90 dB | 90 dB | 80 dB |
Adapters |
MMCX-to 0.1 in (2.54 mm) | 160 dB | 100 dB | 70 dB | 60 dB | 40 dB | 30 dB |
MMCX-to 0.062 in (1.57 mm) | 160 dB | 100 dB | 70 dB | 60 dB | 40 dB | 30 dB |